README.md

Energy Meter Logger

Log your Energy Meter data on a Raspberry Pi and plot graphs of your energy consumption. Its been verified to work with a Raspberry Pi with a Linksprite RS485 shield and reading values from a WEBIQ131D / SDM120. By changing the meters.yml file and making a corresponding [model].yml file it should be possible to use other models.

Requirements

Hardware

Software

Prerequisite

  • Download Raspbian Stretch Lite and Flash on SD-card, e.g. by using Etcher
  • Mount the RS485 shield on the Raspberry Pi’s GPIO header and connect the RS485 cables.
  • Power up Rasberry Pi and setup password (passwd) and SSH, localization, network etc. using

    $ sudo raspi-config
    
  • With raspi-config open, go to 5 Interfacing Options -> P6 Serial and Disable serial login shell and Enable serial port hardware (i.e. NO and then YES)

  • To be able to use the UART you need to disable the built in Bluetooth since it shares the UART. To do so, add the following lines to /boot/config.txt source

    # Disable built in Bluetooth
    dtoverlay=pi3-miniuart-bt
    
  • To disable the serial console, you need to edit the /boot/cmdline.txt file to look like the following row. source

    dwc_otg.lpm_enable=0 console=tty1 root=/dev/mmcblk0p2 rootfstype=ext4 elevator=deadline fsck.repair=yes rootwait
    
  • Install Python Package Manager PIP if not already installed (not installed on Raspbian Lite):

    $ sudo apt-get install python-pip
    
  • Install Git if not already installed (not installed on Raspbian Lite):

    $ sudo apt-get install git
    

Installation

Install InfluxDB

source

Step-by-step instructions
  • Add the InfluxData repository

    $ curl -sL https://repos.influxdata.com/influxdb.key | sudo apt-key add -
    $ source /etc/os-release
    $ test $VERSION_ID = "9" && echo "deb https://repos.influxdata.com/debian stretch stable" | sudo tee /etc/apt/sources.list.d/influxdb.list
    
  • Download and install

    $ sudo apt-get update && sudo apt-get install influxdb
    
  • Start the influxdb service

    $ sudo service influxdb start
    
  • Create the database

    $ influx
    CREATE DATABASE db_meters
    exit

    

Install Grafana

source

Step-by-step instructions
  • Add APT Repository

    $ echo "deb https://dl.bintray.com/fg2it/deb-rpi-1b jessie main" | sudo tee -a /etc/apt/sources.list.d/grafana.list
    
  • Add Bintray key

    $ curl https://bintray.com/user/downloadSubjectPublicKey?username=bintray | sudo apt-key add -
    
  • Now install

    $ sudo apt-get update && sudo apt-get install grafana

    
  • Start the service using systemd:

    $ sudo systemctl daemon-reload
    $ sudo systemctl start grafana-server
    $ systemctl status grafana-server
    
  • Enable the systemd service so that Grafana starts at boot.

    $ sudo systemctl enable grafana-server.service
    
  • Go to http://localhost:3000 and login using admin / admin (remember to change password)

Install Energy Meter Logger:

  • Download and install from Github

    $ git clone https://github.com/samuelphy/energy-meter-logger
    
  • Run setup script (must be executed as root (sudo) if the application needs to be started from rc.local, see below)

    $ cd energy-meter-logger
    $ sudo python setup.py install
    
  • Make script file executable

    $ chmod 777 read_energy_meter.py
    
  • Edit meters.yml to match your configuration

  • Test the configuration by running:

    ./read_energy_meter.py
    ./read_energy_meter.py --help # Shows you all available parameters
    
  • To run the python script at system startup. Add to following lines to the end of /etc/rc.local but before exit:

    # Start Energy Meter Logger
    /home/pi/energy-meter-logger/read_energy_meter.py --interval 60 > /var/log/energy_meter.log &
    

    Log with potential errors are found in /var/log/energy_meter.log